Systematic Feature Filtering in Exploratory Metabolomics: Application toward Biomarker Discovery

Logo poskytovatele
Logo poskytovatele
Logo poskytovatele

Varování

Publikace nespadá pod Ekonomicko-správní fakultu, ale pod Přírodovědeckou fakultu. Oficiální stránka publikace je na webu muni.cz.
Autoři

GADARA Darshak Chandulal COUFALÍKOVÁ Kateřina BOSÁK Juraj ŠMAJS David SPÁČIL Zdeněk

Rok publikování 2021
Druh Článek v odborném periodiku
Časopis / Zdroj Analytical chemistry
Fakulta / Pracoviště MU

Přírodovědecká fakulta

Citace
www https://pubs.acs.org/doi/10.1021/acs.analchem.1c00816
Doi http://dx.doi.org/10.1021/acs.analchem.1c00816
Klíčová slova SPECTROMETRY-BASED METABOLOMICS; LC-MS METABOLOMICS; ANNOTATION; TOOLS; CHALLENGES; SOFTWARE; XCMS
Popis Exploratory mass spectrometry-based metabolomics generates a plethora of features in a single analysis. However, >85% of detected features are typically false positives due to inefficient elimination of chimeric signals and chemical noise not relevant for biological and clinical data interpretation. The data processing is considered a bottleneck to unravel the translational potential in metabolomics. Here, we describe a systematic workflow to refine exploratory metabolomics data and reduce reported false positives. We applied the feature filtering workflow in a case/control study exploring common variable immunodeficiency (CVID). In the first stage, features were detected from raw liquid chromatography-mass spectrometry data by XCMS Online processing, blank subtraction, and reproducibility assessment. Detected features were annotated in metabolomics databases to produce a list of tentative identifications. We scrutinized tentative identifications' physicochemical properties, comparing predicted and experimental reversed-phase liquid chromatography (LC) retention time. A prediction model used a linear regression of 42 retention indices with the cLogP ranging from -6 to 11. The LC retention time probes the physicochemical properties and effectively reduces the number of tentatively identified metabolites, which are further submitted to statistical analysis. We applied the retention time-based analytical feature filtering workflow to datasets from the Metabolomics Workbench (www. metaboloinicsworkbench.org ), demonstrating the broad applicability. A subset of tentatively identified metabolites significantly different in CVID patients was validated by MS/MS acquisition to confirm potential CVID biomarkers' structures and virtually eliminate false positives. Our exploratory metabolomics data processing workflow effectively removes false positives caused by the chemical background and chimeric signals inherent to the analytical technique. It reduced the number of tentatively identified metabolites by 88%, from initially detected 6940 features in XCMS to 839 tentative identifications and streamlined consequent statistical analysis and data interpretation.
Související projekty:

Používáte starou verzi internetového prohlížeče. Doporučujeme aktualizovat Váš prohlížeč na nejnovější verzi.