Off-line MALDI and ICP MS detection of a single record of metallothionein separation

Logo poskytovatele
Logo poskytovatele
Logo poskytovatele

Varování

Publikace nespadá pod Ekonomicko-správní fakultu, ale pod Středoevropský technologický institut. Oficiální stránka publikace je na webu muni.cz.
Autoři

TOMALOVÁ Iva POLANSKÝ Ondřej FOLTYNOVÁ Pavla MILLIONOVÁ Radka PREISLER Jan

Rok publikování 2013
Druh Konferenční abstrakty
Fakulta / Pracoviště MU

Středoevropský technologický institut

Citace
Popis It is estimated that one third of all proteins require metals to carry out their functions. Therefore, the analyses of native metal-protein and metal-metabolite complexes by hyphenated techniques that combine separation with a specific detection is of growing importance. A new concept of an off-line multidetection platform for metalloprotein/metallopeptide analysis of fractions collected from a single run of capillary electrophoresis (CE) or liquid chromatography (LC) is presented. The separation record, i.e. fractions collected on a target, are analyzed sequentially with MALDI MS and SALD ICP MS. Thus, a single separation can yield both proteomic and metallomic information. Moreover, the off-line nature of the analysis provides further possibilities, such as laser-induced fluorescence detection or on target digestion. Here, the approach is demonstrated on the successful reverse phase HPLC-ESI/MALDI/SALD ICP MS analysis of purified rabbit liver metallothionein (MT) isoforms: The MT1a, MT2d and MT2e were eluted out of a C18 column with ammonium acetate buffer (pH 7.5)/ammonium acetate buffer (pH 7.5) in 60% methanol at 27.8, 29.0 and 33.4 min, respectively. Using a flow splitter, the MT isoforms were detected by on-line ESI–TOF MS and the fractions of the separation were simultaneously collected on a suitable target for successive off-line detection by MALDI and SALD ICP MS. CE was successfully coupled to both MALDI and SALD ICP MS. It can offer enhancement of separation efficiency, modified separation selectivity and high sensitivity. On the other hand, low amount of injected samples poses a challenge for both MALDI and SALD ICP MS detection modes. Initial results of CE as a prospective method for separation of MT isoforms will be presented. The influence of liquid junction interface, fraction collector and MALDI-TOF MS settings and other analysis parameters is discussed in detail.
Související projekty:

Používáte starou verzi internetového prohlížeče. Doporučujeme aktualizovat Váš prohlížeč na nejnovější verzi.